Electromagnetic Simulation of an Outer-Rotor Permanent Magnet Synchronous Motor

For an outer-rotor permanent magnet synchronous motor, an electromagnetic simulation design was developed in Motor-CAD. Comparing the 8-pole/36-slot distributed winding with the 20-pole/24-slot fractional-slot concentrated winding, the latter was selected as the final scheme for its lower torque ripple and harmonics and compliance with the 2.12% torque accuracy requirement. Through electromagnetic, thermal-circuit and finite element modeling, steady-state, temperature-rise and multi-condition dynamic verification were completed, showing that the motor meets the requirements in both motor and generator operation.

Share
QR code

Electromagnetic Simulation Design of an Outer-Rotor Permanent Magnet Synchronous Motor

一、Electromagnetic Simulation Modeling of the Motor

1、Determination of Pole Number and Operating Frequency

The design input data given above essentially define the design input requirements for two steady-state operating conditions of the permanent magnet motor, namely rated and peak operation. Several electromagnetic design configurations can satisfy the steady-state performance targets at both conditions. In the simulation study of this motor, two configurations were evaluated: an 8-pole/36-slot/60 Hz distributed-winding scheme and a 20-pole/24-slot/150 Hz fractional-slot concentrated-winding (FSCW) scheme. The preliminary calculation results for both schemes at identical power, torque, and speed are summarized in Table 2:

As shown in the table, the 8-pole/36-slot/60 Hz distributed-winding scheme exhibits relatively high torque ripple ratio and back-EMF harmonics, and therefore fails to meet the torque accuracy class requirement of this motor, ΔkT% ≤ ΔT/TN = 2.12%. In contrast, the 20-pole/24-slot/150 Hz fractional-slot concentrated-winding (FSCW) scheme satisfies the torque regulation accuracy requirement in all the above respects, with even lower higher-order harmonics. Accordingly, the 20-pole/24-slot/150 Hz FSCW scheme was selected as the final electromagnetic design for this motor.

Table 2 Electromagnetic performance indicators of the two pole/slot combination schemes

2、Geometric Model of the Motor Structure

The motor features an outer-rotor, inner-stator configuration. A geometric model closely approximating the actual motor structure was developed in the simulation platform Motor-CAD (see Fig. 3).

Fig. 3 Motor-CAD geometric model of the 20-pole/24-slot/150 Hz outer-rotor PM motor scheme

3、Stator Winding Circuit Model

Winding modeling mainly involves the determination of the winding type, strand parameters, winding pitch, circuit connection, and slot insulation structure. All of these structural parameters can be defined in Motor-CAD (see Fig. 4).

Fig. 4 Stator winding circuit model of the PM motor in the Motor-CAD platform

4、Motor Ventilation and Thermal Circuit Model

The Motor-CAD platform allows the ventilation and heat dissipation structure of the motor to be customized. For the open-type construction of this motor, an axial ventilation arrangement through the end cap was adopted wherever possible, and the fluid settings, flow rate, and ventilation window area were configured so as to closely approximate the actual operating environment. Once configured, the software platform automatically generates a thermal network model of the motor based on its built-in algorithms (see Fig. 5&6).

Fig. 5 Ventilation structure model of the PM motor in the Motor-CAD platform

Fig. 6 Thermal network model of the PM motor in the Motor-CAD platform

5、Finite Element Model of the Motor Magnetic Circuit

The finite element model of the motor magnetic circuit mainly serves to determine the mesh density for the magnetic field analysis. For motors, the number of mesh elements governs both the accuracy and the speed of the calculation. A properly refined mesh yields accurate magnetic field contour plots and field parameters (see Fig. 5& Table 3).

a) Finite element mesh

b) Computed magnetic field contour plot

Fig. 7 Finite element model for the electromagnetic field solution of the outer-rotor PM motor (55kW, steady state)

Table 3 Steady-state magnetic circuit simulation data

6、Establishment of the Motor's Main Materials Database

Performance data of the key materials were collected and a Motor-CAD material database tailored to the simulation of this motor was established. The most critical materials included in the database are: ①the magnetization curve and iron loss curve of 35W270 thin-gauge silicon steel (see Fig. 8); ②the magnetic performance curves of N38UH NdFeB magnet material (see Fig. 9); ③the physicochemical properties and electrical conductivity of the copper conductor.

Fig. 8 Magnetization and iron loss curves of 35W270 thin-gauge silicon steel entered into the database

Fig. 9 Demagnetization characteristic of N38UH NdFeB magnet material entered into the database


二、Steady-State Performance Indicators of the Motor

1、Electromagnetic Performance at the Steady-State Operating Points

As described above, the motor operates in two modes: motor operation in active mode and generator operation in passive mode. The 37 kW, 55 kW, and 75 kW steady-state operating points were selected for each mode, and steady-state electromagnetic performance calculations were carried out at these points. The resulting performance parameters of the motor and the generator at each steady-state point are summarized in Tables 4 and 5.

Table 4 Performance parameters of the motor variable-frequency drive circuit

Table 5 Steady-state electromagnetic performance parameters of the motor


Conclusion: Under motor operation, the permanent magnet motor fully meets the performance requirements at both the rated and peak conditions at the 37 kW/55 kW steady-state points. Under generator operation, the electromagnetic torque reaches 849.27 N·m at the 77 kW steady-state point, which also fully satisfies the 760 N·m requirement for the maximum simulated electric-inertia damping torque.

2、Thermal Performance Calculation at the 55 kW Steady-State Operating Point

Table 6 Thermal calculation data at the 55 kW steady-state operating point

(a)Radial temperature distribution

(b)Axial temperature distribution

Fig. 10 Internal temperature points of the motor at the 55 kW steady-state operating point

(a)Temperature contour plot of the stator slots

 (b)Temperature contour plot of the rotor magnets

Fig. 11 Internal temperature contours of the motor at the 55 kW steady-state operating point


三、Dynamic Operating Characteristics under Multiple Operating Conditions

1、Dynamic Operating Characteristics under Multiple Loads in Motor Mode

Fig. 12 Torque and power - speed dynamic characteristics under motor operation

Table 7 Torque and power - speed characteristic parameters under motor operation

Fig. 13 Torque–efficiency map of the motor under motor operation

Fig. 14 Power–efficiency map of the motor under motor operation


Fig. 15 Efficiency and power factor - speed dynamic characteristics under motor operation

Table 8 Efficiency and power factor - speed characteristic parameters under motor operation

Parameter Table

2、Dynamic Operating Characteristics under Resistive Loads in Generator Mode

Fig. 16 Torque and efficiency - speed dynamic characteristics under resistive loads in generator operation

Fig. 17 Torque–efficiency map under resistive loads in generator operation

Table 9 Torque and efficiency - speed characteristic parameters under resistive loads in generator operation

Fig. 18 Power and efficiency - speed dynamic characteristics under resistive loads in generator operation

Fig. 19 Power–efficiency map under resistive loads in generator operation

Table 10 Power and efficiency - speed characteristic parameters under resistive loads in generator operation


一、Electrical System Configuration

Fig. 65 System block diagram

Weight

Table 19 Material and weight breakdown of motor components















Related Products

Know more about customized solutions

With a full suite of R&D team and manufacturing capacity, we are able to provide solutions to even our most complex challenges.

Know more about customized solutions
    • E-mail:
    • Address: